What Happens When a BMS Fails?

A Battery Management System (BMS) plays a vital role in ensuring the safe and efficient operation of lithium-ion batteries, including LFP and ternary lithium batteries (NCM/NCA). Its primary purpose is to monitor and regulate various battery parameters, such as voltage, temperature, and current, to ensure the battery operates within safe limits. The BMS also protects the battery from being overcharged, over-discharged, or operating outside its optimal temperature range. In battery packs with multiple series of cells (battery strings), the BMS manages the balancing of individual cells. When the BMS fails, the battery is left vulnerable, and the consequences can be severe.
 
1. Overcharging or Over-discharging
One of the most critical functions of a BMSis to prevent the battery from being overcharged or over-discharged. Overcharging is especially dangerous for high-energy-density batteries like ternary lithium (NCM/NCA) because of their susceptibility to thermal runaway. This occurs when the battery’s voltage exceeds safe limits, generating excess heat, which could lead to an explosion or fire. Over-discharging, on the other hand, can cause permanent damage to the cells, especially in LFP batteries, which can lose capacity and exhibit poor performance after deep discharges. In both types, the BMS’s failure to regulate the voltage during charging and discharging can result in irreversible damage to the battery pack.
 
2. Overheating and Thermal Runaway
Ternary lithium batteries (NCM/NCA) are particularly sensitive to high temperatures, more so thanLFP batteries, which are known for better thermal stability. However, both types require careful temperature management. A functional BMS monitors the battery’s temperature, ensuring it stays within a safe range. If the BMS fails, overheating can occur, triggering a dangerous chain reaction called thermal runaway. In a battery pack composed of many series of cells (battery strings), thermal runaway can quickly propagate from one cell to the next, leading to catastrophic failure. For high-voltage applications like electric vehicles, this risk is magnified because the energy density and cell count are much higher, increasing the likelihood of severe consequences.
 
3. Imbalance Between Battery Cells
In multi-cell battery packs, especially those with high voltage configurations such as electric vehicles, balancing the voltage between cells is crucial. The BMS is responsible for ensuring all cells in a pack are balanced. If the BMS fails, some cells may become overcharged while others remain undercharged. In systems with multiple battery strings, this imbalance not only reduces overall efficiency but also poses a safety hazard. Overcharged cells in particular are at risk of overheating, which can cause them to fail catastrophically.
 
4. Power Failure or Reduced Efficiency
A failed BMS can result in reduced efficiency or even total power failure. Without proper management of voltage, temperature, and cell balancing, the system may shut down to prevent further damage. In applications where high-voltage battery strings are involved, like electric vehicles or industrial energy storage, this could lead to a sudden loss of power, posing significant safety risks. For example, a ternary lithium battery pack may shut down unexpectedly while an electric vehicle is in motion, creating dangerous driving conditions.